 TimbyrNode - National Annex and office defaults
===============================================================

TimbyrNode ships with the Eurocode 5 recommended base values (for
example gamma_M 1.30 for solid timber, 1.25 for glulam, 1.30 for
connections). If your National Annex requires different values,
save your own starting values once; every launch then begins with
them.

IMPORTANT: the values are your engineering decision under the
National Annex that applies to your project. TimbyrNode does not
pick a country for you. The "National Annex" window can fill the
values of one country for you as a starting point.


---------------------------------------------------------------
 Set your defaults
---------------------------------------------------------------

  1. Start TimbyrNode and set the calculation settings to the
     values your National Annex requires.
  2. Click the "National Annex" button.
  3. Click "Save current settings as my defaults".

This writes "TimbyrNode_user_default_settings.json" next to
TimbyrNode.exe. Every launch, and every Clear, now starts from
those values.

Also in that window:

  - "Reset session to TimbyrNode factory defaults": puts the
    office settings of the CURRENT session back to the built-in
    values. The open connection (members, fasteners, plates, load
    cases) is not changed, and Undo reverts the reset. Your saved
    file is kept.
  - "Delete my defaults file": removes the file and resets the
    office settings the same way; the next launch starts from the
    built-in values again.


---------------------------------------------------------------
 What it covers
---------------------------------------------------------------

Office settings (applied at launch and on Clear):

  - Partial safety factors: solid timber, glulam, connections,
    panels, and the steel factor gamma_M2.
  - The crack factor k_cr. By default k_cr follows each member's
    material (0.67 solid timber and glulam, 1.0 LVL, or your
    National Annex preset). Only a k_cr you type yourself is saved
    as one value for every member.
  - The fire load factor eta_fi.
  - The National Annex preset name shown on the report cover.
  - Hole and slot clearances (bolts, steel plates, panels).
  - The splitting threshold, the minimum Vz, and the plug-shear,
    rope-effect, block-shear and brittle load-sharing options.

Starting values for a blank connection (applied at launch and on
Clear only; an imported connection keeps its own):

  - Fastener type and grade, steel plate grade, timber class,
    service class and load-duration class.

Not saved: the fire resistance class. Set it for each project.

A saved connection (.tce) ALWAYS opens with its own stored
values. Your defaults file never changes a saved connection; a
setting the file does not store opens at the built-in value.


---------------------------------------------------------------
 One file for the whole office
---------------------------------------------------------------

Copy "TimbyrNode_user_default_settings.json" into the TimbyrNode
folder on every machine (next to its TimbyrNode.exe). Every
machine then starts from the same values. The file is plain text
with a short comment on each line, so you or your IT can review
it in Notepad.


---------------------------------------------------------------
 Built to be safe
---------------------------------------------------------------

  - Every value is checked against the same limits as the input
    field (for example gamma_M 1.0 to 1.5). A value outside them
    is not loaded, and TimbyrNode names it in one line at launch;
    the rest of the file still applies.
  - Save refuses a value that the next launch would not load.
  - A damaged file is renamed to ".bak" and the built-in values
    are used.

If TimbyrNode runs from a read-only folder, an existing defaults
file still loads; only saving a new one needs write access.


---------------------------------------------------------------
 Questions
---------------------------------------------------------------

    support@timbyrnode.com